Heated Total Hydrocarbon Analyzer, FID Model VE7
 

 

Description:

The J.U.M. Engineering HFID Model VE7 is very rugged and versatile 19" rack mount heated total hydrocarbon analyzer for high accuracy, sensitivity and stability.

The Model VE7 uses a hydrogen flame ionization detector (FID) in a heated oven to prevent the loss of high molecular weight hydrocarbons and to provide reliable performance in the analysis of trace level of contaminants in high purity gases, air and other gases.

The permanent heated sample filter is cleaned by backpurging and has a replaceable stainless steel mesh filter disc. A rear adaptor-system allows cold-spot free coupling of a heated sample line inside the heated oven without the need of special tools.

Download VE 7 product brochure as pdf-file (877kB).
(requires Adobe Acrobat Reader 4.0)
Get Acrobat Reader


Major Applications:

  • Stack gas hydrocarbon emissions monitoring
  • Catalytic converter testing
  • Raw exhaust vehicle emissions
  • Detection of trace hydrocarbon levels in purity gases
  • Monitoring of hydrocarbon contaminants in air and other gases
  • Carbon adsorption regeneration control
  • Measuring engine combustion efficiency
  • LEL monitor of solvent-laden air
  • Cryogenics/liquefaction
  • Clean room applications
 

 

1 Technical Data
 
Method of Analysis Flame Ionization Detector
Sensitivity Max. 0.1 ppm CH4
Response Time 0.2 seconds
Zero Drift <1.0% full scale / 24h
Span Drift <1.0% full scale / 24h
Linearity

within 1% of selected range

Oxygen Synergizm < 1.2%
Measuring Ranges (ppm) 0-10,100, 1.000, 10.000, 100.000, others on request
Signal Outputs 0-10VDC and 4-20mA
Display 3 1/2 digit
Sample Pump approx. 2.5 l/min capacity @ operating temp.
Fuel consumption 100% H2 20 ml/min @ 1.5 bar (22 psig)
Fuel consumption H2He 40/60-Mix 90ml/min @ 1.5 bar (22 psig)
Burner Air Consumption NONE, built in burner air supply
Oven Temperature 190°C (374°F)
Temperature Control electronic PID-type controller
Power Requirements 230VAC/50Hz, 850 W or 115VAC/60Hz, 850 W
Ambient Temperature 5-43°C (41-110°F)
Dimensions (W x D x H) 483 mm x 460 mm x 221 mm
Weight approx. 22 kg (46 lbs)
 

 

1 Available Options

   
AMU 7 Automatic range change
APO 7 External automatic programmable backpurge system for the sample filter
AZM 7 Automatic flame ignition
CIM 7 RS 232 data output
DCC 7 Dual concentration threshold alarm, individaully adjustable
ENGA 7 6-digit display, 0-100.000 ppm
FOAS 7 Flame out control with automatic fuel shut off valve
ICM 7 Built-In NMHC Cutter, measure either THC or Methane-Only with one analyzer
LTO 7 Special option for measuring low trace hydrocarbon levels
MBP 7 Integrated bypass pump
MWR 7 Built in mean value calculator
PDA 7 Sample pressure monitor with alarm
RCA 7 0-20 mA analog output instead of 4-20 mA
RCC 7 Remote control range change
RCI0 7 0-20 mA analog output, galvanically isolated
RCI4 7 4-20 mA analog output, galvanically isolated
TPR 7 Built In temperature controller for JUM heated sample line Model TJ 100
 

 

 

Click here for a detailed overview and description of all available HFID options
 

 

J.U.M. reserves the right, at any time and without notice, to change specifications presented in this data sheet and assumes no responsibility for the application or use of the devices described herein.
 

 send literature

 back to analyzer overview

site map 

home